Strom Form: | AC |
---|---|
Anzahl der Pole: | 1 |
Phase: | 3 |
Art: | AC-Schützen |
Größe: | 40~56 |
Kategorie: | AC-3 |
Lieferanten mit verifizierten Geschäftslizenzen
Typ | KNC8-40 |
KNC8-41 | KNC8-44 | KNC8-46 | KNC8-47 | KNC8-48 | KNC8-49 | KNC8-50 | KNC8-52 | KNC8-54 | KNC8-56 | ||
Nennisolationsspannung (V) | 690 | 690 | 690 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | 1000 | ||
Betriebsdauer Strom(380V |
AC-3 | 9 | 12 | 32 | 45 | 63 | 75 | 85 | 110 | 170 | 250 | 400 | |
AC-4 | 3, 3 | 3, 3 | 15, 5 | 24 | 28 | 34 | 42 | 54 | 75 | 110 | 150 | ||
Nennausgänge Dreiphasig Motoren bei 50Hz |
AC-3 AC-4 |
230/220V | 2, 4 | 2, 4 | 8, 5 | 15 | 18, 5 | 22 | 26 | 37 | 55 | 78 | 125 |
400/380V | 4 | 4 | 15 | 22 | 30 | 37 | 45 | 55 | 90 | 132 | 200 | ||
500V | 5, 5 | 5, 5 | 21 | 30 | 41 | 50 | 59 | 76 | 118 | 178 | 284 | ||
690/660V | 5, 5 | 5, 5 | 23 | 39 | 55 | 67 | 67 | 100 | 159 | 235 | 375 | ||
1000V | - | - | - | - | - | 39 | 39 | 65 | 90 | 132 | 250 | ||
400/380V | 1, 48/1, 4 |
1, 48/1, 4 |
7, 5 |
12.6/12 |
14.7/14 |
17.9/17 |
22/21 |
28.4/27 |
40/38 |
61/58 |
85/81 |
||
690/660 | 2, 54/2, 4 |
2, 54/2, 4 |
13 |
21, 8/20, 8 |
25, 4/24, 3 |
30, 9/29, 5 |
38/36 |
49/46, 9 |
69/66 |
105/100 |
147/140 |
||
Mechanische Belastbarkeit (×10 6 ) (0, 8-1, 1) Usa | |||||||||||||
Elektrisch Ausdauer (×10 6 ) |
AC-3 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | |
AC-4 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | 1, 2 | ||
Schaltfrequenz | AC-3 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | 0, 2 | |
AC-4 | 1000 | 1000 | 750 | 1200 | 1000 | 1000 | 850 | 100 | 700 | 700 | 500 | ||
Spulentoleranz | 250 | 250 | 250 | 400 | 300 | 300 | 250 | 300 | 200 | 200 | 150 | ||
Leistung Verbrauch Der Spule (50Hz |
Geschlossen (VA) |
10 | 10 | 12, 1 | 17 | 17 | 32 | 32 | 39 | 58 | 84 | 115 | |
p. F. |
0, 29 | 0, 29 | 0, 28 | 0, 29 | 0, 29 | 0, 23 | 0, 23 | 0, 24 | 0, 26 | 0, 24 | 0, 33 | ||
Colsing (VA) |
6, 8 | 6, 8 | 101 | 183 | 183 | 330 | 330 | 550 | 910 | 1430 | 2450 | ||
p. F. | 0, 82 | 0, 82 | 0, 83 | 0, 6 | 0, 6 | 0, 5 | 0, 5 | 0, 45 | 0, 38 | 0, 34 | 0, 21 | ||
Konventioneller thermischer Strom | 20 | 20 | 55 | 80 | 90 | 100 | 100 | 140 | 210 | 300 | 400 | ||
Konventioneller thermischer Strom von Hilfskontakten |
10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | ||
Nennbetriebsstrom Der Hilfskontakte |
AC-15 380/220V |
6/10 | 6/10 | 4/6 |
4/6 |
4/6 |
4/6 |
4/6 |
4/6 |
4/6 |
4/6 |
4/6 |