Grundlegende Informationen.
Schutz
Overvoltage Short Circuit Overcurrent Unbalanced
Anwendung
Fire Safety Defence Communication Spaceflight
Klassifikation
Beleuchtung / Power
Standby-Zeit
Lang wirkenden Maschinen
Ausgabekapazität
Große Art
Transportpaket
Wooden Case
Herkunft
Shenzhen Guangdong China
Produktbeschreibung
10kVA-400kVA Power Inverter Online UPS Three Phase Online UPS
modelMZT9830L | 10KVA | 15KVA | 20KVA | 30KVA | 40KVA | 60KVA | 80KVA | 100KVA | 120KVA | 150KVA | 200KVA | 300KVA | 400KVA |
Nominalcapacity(KVA) | 10 | 15 | 20 | 30 | 40 | 60 | 80 | 100 | 120 | 150 | 200 | 300 | 400 |
Singe-phase maximum current input(A) | 19 | 29 | 38 | 57 | 76 | 114 | 152 | 189 | 227 | 303 | 379 | 568 | 609 |
Works as well as the principle | On-line power supply,static bypass switch(uninterrupted switch)double conversion technology |
Ac input parameters | Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±25% |
Nominal frequency | 50Hz±10%,60Hz±10% |
The voltage harmonic distortion | <10% |
Soft sart | 0-100%5sec |
bypass | Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±15% |
Nominal frequency | 50Hz/60Hz±10% |
Inverter/bypass(conversin) | 0ms |
The battery | Number of battery unit | 30knots/12v series |
Nominal battery voltage | 360V |
maximum discharge current(A) | 25 | 38 | 51 | 76 | 101 | 152 | 203 | 253 | 305 | 405 | 550 | 760 | 1015 |
Float chargin voltage | 405V(3 months automatic battery to charge,charge voltarge voltage 435V) |
Charging curret | 1A-5A(according to battery capacity setting) |
inverter | The load power factor | 0.8(0.9optinal) |
Number of phase | Three-phase+N+G |
Nominal voltage | 380VAC±1%(The steady-state load),380VAC±3%(The load fluctuation |
Nominal frequency | 50Hz±0.05%,60Hz±0.05%(Battery power) |
Frequency stability:when not in sync | <±0.05% |
When the frequency stability:synchronization | <±5% |
Output waveform | Sine wave |
Total harmonic distortion | Lindar load<2%:The nonlinear load<4% |
Dynamic load voltage transients | <5%(from 0 to 100% more |
Transient recovery time | <10ms(±5%) |
Unbalanced voltage | <±1%(Balance the load voltage),<±3%(Unbalanced load) |
Overload capacity | Overload for ten min later turn the bypass,125% 150%overload lasts1 min after bypass |
The inverter efficiency and load by 100% | 95% |
The system structure | Total efficiency of 100% load | 91%,95%.ECO |
Computer ommunication interface | Rs232,(Rs485.Network remote monitoring software) |
Operating temperature | 0-40ºC |
Relating humidity | 0-90% Without any condensation |
Running high | <1500m(each additional,100meters power fell by 1%, the highest4000meters |
Cooling way | Forced vention(temperature control) |
Noise(db) | <65 |
The body color | black |
The input cable | The bottom/bcak |
Easy to maintain | On/about/in front of the plane can be opened |
Lnput device | Terminal row |
The output device | Terminal row |
Size (D×W×H) | 725×450×1135 | 855×450×1235 | 715×855×1500 | 1100×900×1700 | 1200×1500×1800 | 1300×1800×1800 |
The host weight(kg) | 200 | 250 | 340 | 400 | 480 | 650 | 900 | 1200 | 1300 | 1480 | 2000 | 2100 | 2500 |
Option to | Rs485,weaver board,network management system,battery testing sydstem,lightning protection devices for option |
is required to order |
The characteristics of 3C3 series Three-phase input and output High frequency on-line UPS : Adopted double conversion design, To provide a safe and reliable power supply for the followingsituation: The grid without power, mains voltage too high or too low, instantaneous voltage drop ordamped oscillation, high voltage pulse, voltage fluctuation, surge voltage, harmonic distortion,noise interference, the condition of frequency fluctuations, etc. This product is widely used in sm alland medium sized data center, network management center, enterprise server room and generalindustrial environmentsN+X parallel connection redundancy : The machine has the function of parallel connection, Don'tneed to increase the external accessories, Can achieve the maximum of 6 ~ 8 UPS parallel, The user canbe low cost system expands, N for load required the fewest number of UPS, X represents the numberof redundant , The greater the X system reliability will be higher, Adopts the advanced control strategy,In weaver redundant work condition, the system can support sharing a set of batteries, save theinvestment cost of users,The intelligent battery charge and discharge management: Advanced intelligent charging waysthrough the control of the CPU, according to different environmental conditions, Fixed chargingparameters, Provide the best way of charging the battery, Design a variety of charging ways, accord ingto the type of battery, battery section number and the stat us of the battery to choose the best way ofcharging. Scientific way of charging, to prolong the service life of the battery., And can be addedwiththe charging unit, make many battery back charging time is shortened greatly.Positive and positive operation maintenance function: Give full consideration to the user spaceeffective utilization; Modular design and the positive maintenance, greatly shorten the troubleshoo tingof the machine time, improve the usability of UPS.Provide the ECO mode ,whole machine efficiency reached 93% ~ 94%, Reduce the UPS power loss;Can adapt to bad power grid environment.Excellent input frequency range make UPS can adapt todifferent power supply devices,IGBT High frequency intelligent rectifier inverter technology, The input power factor above 0.99, T heinput current harmonic as low as 3%; The output voltage current performance is more outstanding.Strong ability of overload: 110-125% of load can be normal operation for 10 minutes, 125-150% of loadcan be normal operation for 1 minute. And it have Output short circuit protection ability. Welcome your enquiryContact me :Shawn Zhang
Die Anschrift:
Floor 9, Building3, Jincheng Park, Dalang Street, Longhua District, Shenzhen, China
Unternehmensart:
Hersteller/Werk
Geschäftsbereich:
Bau- und Dekomaterial, Beleuchtung, Computerartikel, Elektronik, Industrielle Anlagen und Zusatzteile, Konsumelektronik, Messinstrumente, Mineralien und Energie, Produktionsmaschinen, Sicherheit und Schutz
Zertifizierung des Managementsystems:
ISO 9001
Firmenvorstellung:
Meze Unternehmen wurde 1999 gegründet, so weit, hat sich zu einem umfassenden Energieversorgungsunternehmen entwickelt, Produkte umfassen: USV unterbrechungsfreie Stromversorgung, Mikrocomputer berührungslose elektronische AC geregelte Stromversorgung, EPS Notstromversorgung, etc. Hauptbereich: Die Finanz-, Regierung, Forschungsinstitute, Transport, Luft-und Raumfahrt, Elektronik, Medizin, Dienstleistungen, etc. Um die globale Elektronik-und Kommunikationsindustrie für Power Equipment zu erfüllen ist zunehmend energische Marktnachfrage, aufgrund der Notwendigkeit der Entwicklung, shenzhen Meze Power Technology Co., Ltd wurde im Jahr 2008 gegründet (spezialisiert auf USV-Netzfrequenz, geregelte Stromversorgung, Und Transformator) im gleichen Jahr registriert Meze Electronics Co., Ltd (Klemmenblöcke, alle Zubehör von PCB), im Jahr 2011 registriert shenzhen Meze mechanische und elektrische Co., Ltd. (SMT Bestückungsmaschine und Zubehör).
Bestehende Anzahl von Mitarbeitern: 180-180 Mitarbeiter, mit Fläche: 3000 Quadratmetern, hat das Unternehmen die hohe Technologie und reiche Erfahrung, Produkte von bekannten internationalen Marken in Europa, ist verpflichtet, Kunden mit der gesamten Palette von qualitativ hochwertigen Hochleistungs-stabile Stromversorgung Schutz. Mit der international fortschrittlichen intelligenten digitalen USV-Stromversorgungstechnologie und der fortschrittlichsten Präzisionsreinigung. Bieten Sie die fortschrittlichsten, modernsten, zuverlässigsten und leistungsstärksten Lösungen.