Grundlegende Informationen.
Spannung
Nieder-und Mittelspannung Kabel
Draht Kernmaterial
Rot Kupferdraht
Bescheinigung
ISO, CE, UL
Transportpaket
Sea Worthy Packing
Spezifikation
National Standard
Herkunft
Yanggu, Shandong, China
Produktbeschreibung
0.6/1KV or Below PVC Insulated and Sheathed Power Cable
This product is used for the Power Transmission of Electrical Circuit of rated AC Voltage 0.6/1KV.
Production Standard:
China Standard: GB/T12706.1
IEC Standard: IEC60502.
Feature:
Cable Conductor Long time working Temperature should be less than 70ºC
During Short Circuit (Max Time should be less than 5 Seconds), Max Temperature of Cable Conductor is less than 160ºC
Surrounding Environmental Temperature during Cable Laying should not be less than 0ºC.
Basic Model
Model | Name | Application |
Copper | Al |
VV | VLV | PVC Insulated PVC sheathed Power Cable | It is used inside Room, Tunnel, Cable Groove or Pipes. Cable cannot be hit by External Mechanical Force. |
VV22 | VLV22 | PVC Insulated PVC sheathed Steel Strip Armored Power Cable | This is laid underground, it Can bear some External Mechanical Force, But it cannot bear large Pulls. |
Note:
"Flame Retardant" "Fire Resistant" Cable can also be offer, For "Flame Retardant" Type, "ZR-" should be added before the previous model code, For "Fire Resistant" Cable, "ZH-" Should be added.
VV32 Type and VLV32 Type Steel Wire Armored Power Cable can also be offered. Single Core Steel Wire Armored Power should be Magnetically isolated
Products Scope:
Model | Core | Cross Section MM2 |
Copper | Al |
VV VV22 | VLV VLV22 | 1 | 1.5~500 2.5~500 10~500 |
VV VV22 | VLV VLV22 | 2 | 1.5~185 2.5~185 4~185 |
VV VV22 | VLV VLV22 | 3 | 1.5~300 2.5~300 4~300 |
VV VV22 | VLV VLV22 | 4 | 2.5~300 2.5~300 4~300 |
VV VV22 | VLV VLV22 | 3+1 | 4~300 4~300 |
Note:
5 Cores Cable can also be offered
Armor Layer of Single Core Armored Cable for AC System should be wrapped with Non-Magnetic Metal Strips.
Technical Parameters:
1): Max DC Resistance of the Conductor in 20ºC should meet Requirement of 2nd Type Conductor in the Standard of GB/T3956
2): A.C. Voltage Test: Single Core Non-Shielding Core should be immersed into water for 1 hour and impose Testing Voltage of 3.5KV/5 Min between the Conductor and Water. For Multi-Core Cable, Please input Testing Voltage of 3.5KV/5 Min between each core and all the rest cores, after testing, Insulation layer should be Breakdown Free.
Approximate O.D and Weight of the Cable
Core× Nominal Cross Section mm2 | Approximate O.D mm | Approximate Weight kg/km | Approximate O.D mm | Approximate Weight kg/km |
VV | VLV | VV22* | VLV22* |
1×1.5 | 5.8 | 50 | / | / | / | / |
1×2.5 | 6.2 | 62 | 47 | / | / | / |
1×4 | 7.1 | 87 | 63 | / | / | / |
1×6 | 7.6 | 110 | 75 | / | / | / |
1×10 | 8.9 | 166 | 96 | 12.4 | 346 | 270 |
1×16 | 9.9 | 234 | 133 | 13.4 | 432 | 331 |
1×25 | 11.7 | 345 | 186 | 15.2 | 574 | 414 |
1×35 | 12.6 | 450 | 229 | 16.2 | 692 | 475 |
1×50 | 14.6 | 585 | 276 | 18.1 | 863 | 553 |
1×70 | 16.3 | 800 | 366 | 19.8 | 1133 | 700 |
1×95 | 18.5 | 1065 | 475 | 22.0 | 1432 | 844 |
1×120 | 20.2 | 1328 | 586 | 23.7 | 1705 | 962 |
1×150 | 22.5 | 1600 | 702 | 26.0 | 2044 | 1120 |
1×185 | 24.8 | 1990 | 850 | 28.3 | 2438 | 1296 |
1×240 | 27.8 | 2546 | 1060 | 31.5 | 3057 | 1570 |
1×300 | 30.7 | 3140 | 1292 | 34.2 | 3926 | 2070 |
1×400 | 34.7 | 4127 | 1651 | 38.0 | 5084 | 2608 |
1×500 | 39.0 | 5259 | 2016 | 43.0 | 6295 | 2936 |
2×1.5 | 10.4 | 118 | / | / | / | / |
2×2.5 | 11.3 | 151 | 118 | / | / | / |
2×4 | 13.0 | 210 | 159 | 16.0 | 424 | 374 |
2×6 | 13.9 | 263 | 192 | 17.1 | 494 | 425 |
2×10 | 16.5 | 394 | 242 | 19.8 | 665 | 497 |
2×16 | 18.6 | 541 | 334 | 21.8 | 845 | 638 |
2×25 | 22.0 | 794 | 468 | 25.3 | 1154 | 827 |
2×35 | 24.2 | 1037 | 585 | 27.5 | 1436 | 982 |
2×50 | 20.3 | 1236 | 592 | 23.6 | 1580 | 940 |
2×70 | 22.7 | 1647 | 745 | 26.0 | 2210 | 1302 |
2×95 | 26.2 | 2189 | 966 | 29.1 | 2800 | 1530 |
2×120 | 28.8 | 2640 | 1144 | 32.6 | 3400 | 1850 |
2×150 | 32.2 | 3280 | 1410 | 36.2 | 4150 | 2198 |
2×185 | 35.8 | 4006 | 1703 | 39.5 | 5025 | 2592 |
3×1.5 | 10.6 | 142 | / | / | / | / |
3×2.5 | 11.7 | 187 | 139 | / | / | / |
3×4 | 13.6 | 264 | 189 | 16.6 | 489 | 413 |
3×6 | 14.7 | 335 | 226 | 17.7 | 578 | 472 |
3×10 | 17.4 | 514 | 290 | 20.4 | 801 | 560 |
3×16 | 19.7 | 729 | 418 | 22.7 | 1058 | 743 |
3×25 | 23.4 | 1085 | 596 | 26.4 | 1470 | 979 |
3×35 | 25.8 | 1430 | 748 | 28.8 | 2148 | 1370 |
3×50 | 25.5 | 1820 | 839 | 28.5 | 2457 | 1489 |
3×70 | 28.4 | 2400 | 1080 | 31.7 | 3122 | 1768 |
3×95 | 32.8 | 3155 | 1418 | 36.7 | 4055 | 2218 |
3×120 | 35.7 | 3982 | 1747 | 39.6 | 4925 | 2606 |
3×150 | 40.0 | 4950 | 2135 | 44.0 | 6050 | 3154 |
3×185 | 44.4 | 6156 | 2610 | 48.6 | 7299 | 3721 |
3×240 | 49.7 | 7886 | 3308 | 53.9 | 9223 | 4584 |
3×300 | 54.3 | 9647 | 4059 | 58.7 | 11022 | 5423 |
4×2.5 | 12.2 | 225 | 166 | / | / | / |
4×4 | 15.0 | 332 | 231 | 18.0 | 581 | 480 |
4×6 | 16.2 | 430 | 270 | 19.2 | 703 | 551 |
4×10 | 19.7 | 641 | 393 | 22.7 | 891 | 637 |
4×16 | 22.0 | 902 | 499 | 25.0 | 1175 | 771 |
4×25 | 26.0 | 1438 | 766 | 29.0 | 1998 | 1347 |
4×35 | 28.7 | 1815 | 919 | 31.7 | 2585 | 1660 |
4×50 | 30.4 | 2380 | 1091 | 33.4 | 3100 | 1819 |
4×70 | 33.8 | 3202 | 1398 | 37.0 | 4039 | 2228 |
4×95 | 38.2 | 4300 | 1860 | 41.5 | 5200 | 2800 |
4×120 | 42.0 | 5269 | 2186 | 45.5 | 6400 | 3320 |
4×150 | 46.4 | 6554 | 2748 | 49.9 | 7806 | 3958 |
4×185 | 51.2 | 8090 | 3325 | 54.9 | 9442 | 4700 |
4×240 | 55.3 | 10355 | 4056 | 59.0 | 11887 | 5734 |
4×300 | 64.5 | 12776 | 4950 | 68.2 | 14356 | 6995 |
3×4+1×2.5 | 14.5 | 310 | 215 | 17.5 | 543 | 447 |
3×6+1×4 | 16.1 | 403 | 268 | 19.1 | 661 | 526 |
3×10+1×6 | 18.9 | 600 | 363 | 21.9 | 894 | 625 |
3×16+1×10 | 21.6 | 858 | 505 | 24.6 | 1195 | 807 |
3×25+1×16 | 25.0 | 1315 | 693 | 28.0 | 1679 | 1082 |
3×35+1×16 | 27.6 | 1645 | 834 | 30.6 | 2243 | 1458 |
3×50+1×25 | 29.6 | 2124 | 996 | 32.6 | 2867 | 1736 |
3×70+1×50 | 33.2 | 2867 | 1285 | 36.2 | 3698 | 2099 |
3×95+1×50 | 38.0 | 3824 | 1664 | 42.1 | 4796 | 2636 |
3×120+1×70 | 41.5 | 4784 | 2060 | 45.5 | 5900 | 3129 |
3×150+1×70 | 44.6 | 5790 | 2473 | 48.4 | 6921 | 3623 |
3×185+1×95 | 49.7 | 7164 | 3050 | 54.2 | 8437 | 4369 |
3×240+1×120 | 55.9 | 9414 | 3842 | 60.3 | 11163 | 5586 |
3×300+1×150 | 61.6 | 11749 | 4920 | 66.0 | 13465 | 6445 |
Armor Layer of Single Core Armored Cable for AC System should be wrapped with Non-Magnetic Metal Strips.
Single Core Steel Wire Armored Power should be magnetically isolated
7. Cable Capacity:(0.6/1kV)
Cabling in Open Air:
Center Distance when Single Core Cables are paralleled laid: 185MM2 or Below: 2 Times of the Cable Diameter240MM2 or Above: 90MM.
2): Max Working Temperature of Conductor: 70ºC,Surrounding Temperature: 30ºC.
Correction Factor of Capacity under Different Air Temperature:
Air Temperature:ºC | 20 | 25 | 30 | 35 | 40 | 45 |
Correction Factor | 1.12 | 1.06 | 1.00 | 0.94 | 0.87 | 0.79 |
Die Anschrift:
Xiangguang Qianyi (Ecology) Industrial Zone, Yanggu County, Liaocheng, Shandong, China
Unternehmensart:
Hersteller/Werk, Handelsunternehmen
Geschäftsbereich:
Elektronik
Firmenvorstellung:
YangguXinhui Cable co. Ltd. Befindet sich in Yanggu County, 10 Kilometer nördlich der verheißungsvollen Licht Milliarden von (ökologischen) Industriepark, nach Liaoyang Autobahn, Peking-kowloon Bahn, Chat, in der Nähe der Stadt Liaocheng, Transport, Kommunikation, Logistik ist sehr bequem. Unternehmen wurde im Jahr 1997 gegründet, ist in Kabel R & D und Herstellung von modernen Unternehmen spezialisiert. Nach Jahren der Entwicklung, hat sich gebildet deckt eine Fläche von fast 160 mu, Gebäudefläche von 2,5 Quadratmetern, jährliche Produktionswert von 380 Millionen Yuan, hat mehr als 200 Sätze der Produktion, Zusatzausrüstung Fast alle Arten von Prüfgeräten mehr als 40 Sätze von Mitarbeitern fast 380 Menschen, Zwischen-und Senior-technisches Personal 110 Menschen, Qualitätsprüfung (Messung) prüfen Prüfpersonal 10 Menschen, können verschiedene Spezifikationen von Draht und Kabel Tausende von produzieren, Und in der Kabelindustrie hat einen gewissen Einfluss der Provinz der großen Draht- und Kabelhersteller.
Die Produktion von Polyvinylchlorid isolierte Draht und Kabel Unsere Fabrik im Jahr 2002 produziert gewann einige nationale Elektriker-zertifizierungskommission und Sicherheitszertifizierung, flammhemmende, feuerfeste Draht und Kabel im Juni 2013 durch Brandtyp Zulassung, Netzkabel, Steuerkabel, im Jahr 2001 gewann die nationale Industrieprodukte Produktionslizenz, Im Dezember 2002 hat die Zertifizierung des Qualitätsmanagementsystems ISO9001: 2000 bestanden. Reis.