Input voltage range |
3PH AC380V±15% |
Input frequency |
47~63Hz |
Output frequency range |
0~500Hz |
Overload capability |
G type:150% rated current for 60s; 180% rated current for 3s P type:120% rated current for 60s; 150% rated current for 3s |
Torque boost |
Auto Torque boost Manual Torque boost; 0.1%~30.0%. |
V/F curve V/F |
Four modes : Line , Multi-point , Square V/F curve, V/F separation |
Jog control |
Jog frequency range:0.00Hz to F0-10(Max frequency) |
Accelerate/Decelerate curve |
Line or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range of Acc/Dec Time0.0~65000.00s. |
DC brake |
DC brake frequency: 0.00Hz to Maximum frequency brake time: 0.0 to 36.0s brake current value: 0.0 to 100% |
Simple PLC, Multi-speed |
16-speed operating through built-in PLC or control terminal |
Built-in PID |
Close loop control system can be formed easily by using PID |
Automatic voltage regulating (AVR) |
Output voltage is regulated when voltage of the power network changes |
Overvoltage and over current stall control |
During operation automatically limits the inverter output current and bus voltage, to prevent fan over current and overvoltage trip. |
Rapid current limiting function |
Minimizing flow failures, protect the normal operation of the inverter |
Instantaneous stop non-stop |
Load feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted. |
Speed tracking start |
For high-speed rotation of the motor speed identification, impact- free smooth start |
Rapid current limit |
Rapid software and hardware limiting technology to avoid frequent converter over current fault. |
Virtual IO |
Five sets of virtual DO, five sets of virtual DI, enables easy logic control. |
Timing Control |
Timing control: set the time range 0.0Min~6500.0Hour |
Multi-motor switch |
Two independent motor parameters, enabling two motors switching control |
Bus Support |
Two independent Modbus communication, CAN-Link |
Command source |
Given the control panel, control terminal, serial communication port given. It can be switched by a variety of ways. |
Torque boost |
Auto Torque boost Manual Torque boost ; 0.1%~30.0%. |
Frequency source |
Nine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways. |
Auxiliary frequency source |
Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary frequency tuning, frequency synthesis. |
Input terminal |
Six digital input terminals, one only supports 50khz high pulse input Two analog input terminals, one support 0V~10V voltage input One support 0 ~ 10V voltage input or 0 ~ 20mA current input |
Output terminal |
One high-speed pulse output terminal (optional open collector type), support of square wave 0 ~ 50kHz signal output One digital output terminal One relay output terminals Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output |
Display and operation |
|
LED display |
Display parameters and status information |
The key lock and function selection |
Achieve some or all of the keys locked, scope definition section keys to prevent misuse. |
Protection function |
Input/output phase failure protection ,Overcurrent protection ;Over voltage protection; Undervoltage protection; Overheat protection ; Overload protection |
Options |
Brake assembly, PG card |
Environment |
|
Application environment |
In-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt . |
Altitude |
Lower than 1000m |
Vibration |
Less than 5.9m/s(0.6g) |