Ningbo Deli Electronics Co., Ltd. Preface Thank you for purchasing DL-C101A, an audible and visual carbon monoxide alarm equipped with LCD concentration display developed by our Company. Be sure to carefully read this product user manual prior to using to assist you in the proper usage. This alarm can only remind you of carbon monoxide hazard, but cannot prevent the occurrence of carbon monoxide. Please evacuate to safe areas and call professionals for treatment when hearing the alarm from the alarm.
Content Overview: Chapter 1 Alarm Usage and Function Introduction
DL-C101A Carbon Monoxide Alarm Usage
1.1 Electric Parameters of DL-C101A Carbon Monoxide Alarm 1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm 1.3 Battery Installation and Indications 1.3.1 Battery Installation 1.3.2 Battery Level Indication 1.3.3 Information Displayed on LCD Screen 1.4 Alarm and Audio Indications 1.4.1 Sound and Light Indications 1.4.2 Alarm Status 1.4.3 Display of Carbon Monoxide Concentration Value
1.5 Test and Mute Functions 1.5.1 Manual Test 1.5.2 Mute Functions
1.6 Sensor Failure Self-test Error Message and Treatment 1.6.1 Sensor Failure Test Message 1.6.2 Sensor Failure Treatment 1.7 Alarm Record View 1.7.1 Record Data Operation Options and Display 1.7.2 Alarm Record View and Purge 1.8 Alarm's End-of-life Warning
Chapter 3 Alarm Maintenance and Cleaning 3. Daily Maintenance and Precautions 3.1 Impact of Other Chemical Gases on Alarm 3.2 Alarm Cleaning and Maintenance 3.3 FAQ and Material Circumstance 3.4 Hazards from Unauthorized Disassembly and Repair
Chapter 4 Additional Information of Carbon Monoxide 4. Additional Information 4.1 Knowledge of Carbon Monoxide 4.2 How Carbon Monoxide Is Generated 4.3 Impact of Carbon Monoxide on Human Health 4.4 Threat of Carbon Monoxide on Families 4.5 Carbon Monoxide Poisoning Symptom 4.6 Carbon Monoxide Poisoning Treatment 4.7 How to Deal with Harmful Carbon Monoxide or Carbon Monoxide Alarm Alarms
Chapter 1 Alarm Usage and Function Introduction
DL-C101A Carbon Monoxide Alarm Usage
Electric Parameters of DL-C101A Carbon Monoxide Alarm
Effectively Detectable Gases: Carbon Monoxide Detection Mode: Electrochemical Sensor Dimensions: Weight: 196 g (Battery included) Type: Type B (Without Control Output) Software Version:The version number in the product label paper refers to the software release version number Service Voltage:DC 4.5V (Three 1.5 VPAIRDEER LR6/AA High-energy Alkaline Batteries for 18 Months) Low Voltage Indication:The alarm indications low voltage for voltage less than 3.5V, in which case the sensor only keeps 30 days of standby status or 2 hours of continuous alarm. Work Environment:Temperature from 0ºCto 45ºCand relative humidity of 0-90%RH Static Working Current: <35uA Alarm Current:<85mA Alarm Sound:>85dB (1M Distance) Indication Concentration Range: 25-600PPM with error ±10%, "Hco" will display when the concentration over 600PPM. Temperature Indication: -15-50ºC, the temperature and 0PPM must be indicated alternately about 22 seconds when CO concentration less than 25PPM. Electric Quantity: Full, normal, low and shortage; Indicate 4 electric quantity states.
Carbon Monoxide Alarm Level: Execute EN50291 Standard
Carbon Monoxide Concentration
Without Alarm Before
With Alarm Before
33±3PPM
120 Minutes
--
55±5ppm
60 Minutes
90 Minutes
110±10ppm
10 Minutes
40 Minutes
330±30ppm
--
3 Minutes
Remove Alarm Status: It is necessary to place the alarm in the air with CO concentration less than 40PPM after trigging and the alarm will be automatically removed within 6 minutes. Power Indicator: Blink once every 45 seconds. Failure Detection:Conduct self-inspection every two minutes. Suitable Occasions: Home, hotel rooms, warehouses, basements Effective Use Period: 10 years
Factory Accessories:
Serial No.
Accessory Name
Quantity
1
DL-C101A
1PC
2
Mounting Plate
1PC
3
AA Alkaline Battery
3PCS
4
Mounting Screw
2PCS
5
Plastic Expansion
2PCS
1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm DL-C101A alarm`s basic function is only for the detection of carbon monoxide with the basic components as shown below.
Chapter 4 Additional Information of Carbon Monoxide 4. Additional Information 4.1 Knowledge of Carbon Monoxide 4.2 How Carbon Monoxide Is Generated 4.3 Impact of Carbon Monoxide on Human Health 4.4 Threat of Carbon Monoxide on Families 4.5 Carbon Monoxide Poisoning Symptom 4.6 Carbon Monoxide Poisoning Treatment 4.7 How to Deal with Harmful Carbon Monoxide or Carbon Monoxide Alarm Alarms
Chapter 1 Alarm Usage and Function Introduction
DL-C101A Carbon Monoxide Alarm Usage
Electric Parameters of DL-C101A Carbon Monoxide Alarm
Effectively Detectable Gases: Carbon Monoxide Detection Mode: Electrochemical Sensor Dimensions: Weight: 196 g (Battery included) Type: Type B (Without Control Output) Software Version:The version number in the product label paper refers to the software release version number Service Voltage:DC 4.5V (Three 1.5 VPAIRDEER LR6/AA High-energy Alkaline Batteries for 18 Months) Low Voltage Indication:The alarm indications low voltage for voltage less than 3.5V, in which case the sensor only keeps 30 days of standby status or 2 hours of continuous alarm. Work Environment:Temperature from 0ºCto 45ºCand relative humidity of 0-90%RH Static Working Current: <35uA Alarm Current:<85mA Alarm Sound:>85dB (1M Distance) Indication Concentration Range: 25-600PPM with error ±10%, "Hco" will display when the concentration over 600PPM. Temperature Indication: -15-50ºC, the temperature and 0PPM must be indicated alternately about 22 seconds when CO concentration less than 25PPM. Electric Quantity: Full, normal, low and shortage; Indicate 4 electric quantity states.
Carbon Monoxide Alarm Level: Execute EN50291 Standard
Carbon Monoxide Concentration
Without Alarm Before
With Alarm Before
33±3PPM
120 Minutes
--
55±5ppm
60 Minutes
90 Minutes
110±10ppm
10 Minutes
40 Minutes
330±30ppm
--
3 Minutes
Remove Alarm Status: It is necessary to place the alarm in the air with CO concentration less than 40PPM after trigging and the alarm will be automatically removed within 6 minutes. Power Indicator: Blink once every 45 seconds. Failure Detection:Conduct self-inspection every two minutes. Suitable Occasions: Home, hotel rooms, warehouses, basements Effective Use Period: 10 years
Factory Accessories:
Serial No.
Accessory Name
Quantity
1
DL-C101A
1PC
2
Mounting Plate
1PC
3
AA Alkaline Battery
3PCS
4
Mounting Screw
2PCS
5
Plastic Expansion
2PCS
1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm DL-C101A alarm`s basic function is only for the detection of carbon monoxide with the basic components as shown below.
Chapter 4 Additional Information of Carbon Monoxide 4. Additional Information 4.1 Knowledge of Carbon Monoxide 4.2 How Carbon Monoxide Is Generated 4.3 Impact of Carbon Monoxide on Human Health 4.4 Threat of Carbon Monoxide on Families 4.5 Carbon Monoxide Poisoning Symptom 4.6 Carbon Monoxide Poisoning Treatment 4.7 How to Deal with Harmful Carbon Monoxide or Carbon Monoxide Alarm Alarms
Chapter 1 Alarm Usage and Function Introduction
DL-C101A Carbon Monoxide Alarm Usage
Electric Parameters of DL-C101A Carbon Monoxide Alarm
Effectively Detectable Gases: Carbon Monoxide Detection Mode: Electrochemical Sensor Dimensions: Weight: 196 g (Battery included) Type: Type B (Without Control Output) Software Version:The version number in the product label paper refers to the software release version number Service Voltage:DC 4.5V (Three 1.5 VPAIRDEER LR6/AA High-energy Alkaline Batteries for 18 Months) Low Voltage Indication:The alarm indications low voltage for voltage less than 3.5V, in which case the sensor only keeps 30 days of standby status or 2 hours of continuous alarm. Work Environment:Temperature from 0ºCto 45ºCand relative humidity of 0-90%RH Static Working Current: <35uA Alarm Current:<85mA Alarm Sound:>85dB (1M Distance) Indication Concentration Range: 25-600PPM with error ±10%, "Hco" will display when the concentration over 600PPM. Temperature Indication: -15-50ºC, the temperature and 0PPM must be indicated alternately about 22 seconds when CO concentration less than 25PPM. Electric Quantity: Full, normal, low and shortage; Indicate 4 electric quantity states.
Carbon Monoxide Alarm Level: Execute EN50291 Standard
Carbon Monoxide Concentration
Without Alarm Before
With Alarm Before
33±3PPM
120 Minutes
--
55±5ppm
60 Minutes
90 Minutes
110±10ppm
10 Minutes
40 Minutes
330±30ppm
--
3 Minutes
Remove Alarm Status: It is necessary to place the alarm in the air with CO concentration less than 40PPM after trigging and the alarm will be automatically removed within 6 minutes. Power Indicator: Blink once every 45 seconds. Failure Detection:Conduct self-inspection every two minutes. Suitable Occasions: Home, hotel rooms, warehouses, basements Effective Use Period: 10 years
Factory Accessories:
Serial No.
Accessory Name
Quantity
1
DL-C101A
1PC
2
Mounting Plate
1PC
3
AA Alkaline Battery
3PCS
4
Mounting Screw
2PCS
5
Plastic Expansion
2PCS
1.2 Brief Introduction to DL-C101A Carbon Monoxide Alarm DL-C101A alarm`s basic function is only for the detection of carbon monoxide with the basic components as shown below.