Application: | Insulators, Electrical Winding Insulation, Winding Wire Coating Insulation, Electrical Base, Shell, Motor, Insulating Varnish, Switch Baseplate |
---|---|
Type: | Insulation Sheet |
Chemistry: | Hybrid Insulation |
Material: | Vulcanized Fiber |
Thermal Rating: | F 155 |
Maximum Voltage: | 10KV~20KV |
Lieferanten mit verifizierten Geschäftslizenzen
Elemente
|
Einheit
|
Standard
|
Ergebnis
|
||
Dicke
|
Mm
|
0,6±0,05
|
0,634
|
||
Dichte
|
G/cm3
|
0,5mm-0,9mm
1,0mm-2,0mm 2,1mm-5,9mm ≥6,0mm |
≥1,1
≥1,15 ≥1,15 ≥1,20 |
1,17
|
|
Durchschlagspannung
(23±1 C Temperatur)
|
KV/mm
|
0,5mm-0,9mm
|
≥6,0
|
__
|
|
1,0mm-2,0mm
|
≥5,0
|
||||
2,1mm-5,0mm
|
≥3,0
|
||||
5,1mm-12,0mm
|
≥2,5
|
||||
Zugfestigkeit des Querschnitts
|
Kn/m2
|
0,5mm-0,9mm
|
MD
|
≥5,5 X 104
|
MD 1,31 X 105
CMD 6,31 X 105 |
CMD
|
≥3,5 X 104
|
||||
1,0mm-2,0mm
|
MD
|
≥6,0 X 104
|
|||
CMD
|
≥3,5 X 104
|
||||
2,1mm-3,5mm
|
MD
|
≥6,0 X 104
|
|||
CMD
|
≥4,0 X 104
|
||||
≥6,0mm
|
MD
|
≥5,0 X 104
|
|||
CMD
|
≥3,0 X 104
|
||||
Dehnungsgrad
|
%
|
__
|
2,1
|
||
__
|
2,6
|
||||
Volumenwiderstand
|
Ω cm
|
≥108
|
1,9 x 1011
|
||
Wasseraufnahme
|
%
|
≤65
|
82,5
|
||
Verleimkoeffizient
|
N/m
|
≥200
|
231
|
||
Zinkchloridgehalt
|
0,63
|
≤0,20
|
0,07
|
||
Feuchtigkeitsgehalt
|
0,78
|
6-10
|
6,5
|
||
Aschegehalt
|
0,9
|
≤2,5
|
0,59
|
Lieferanten mit verifizierten Geschäftslizenzen