After-sales Service: | Life Time |
---|---|
Warranty: | 12 Months Excellent After-Sales Serivce |
Anwendung: | Elektromagnetische Instrument, Electrical Calibration |
Leistung: | Strom |
Kundenspezifische: | Kundenspezifische |
Transportpaket: | Package for Exporting |
Lieferanten mit verifizierten Geschäftslizenzen
☆ Kalibrierung Der Spannungsquelle/Des Voltmeters Mit Großer Frequenz. |
|
☆ Kalibrieren Von Weitfrequenz-Spannungstidern / Transformatoren. |
|
|
|
Spezifikation | Nenneingangsspannung ( V ) | Maximale Eingangsspannung ( V ) | Nennausgangsspannung ( V ) | Proportionale Unsicherheit ( k=2, ppm ) | Temperaturkoeffizient ( ppm/K ) |
TH0150-A-10V | 10 | 20 | 1 | 20 | 2 |
TH0150-A-20V | 20 | 30 | 1 | 20 | 2 |
TH0150-A-50V | 50 | 60 | 1 | 20 | 2 |
TH0150-A-100V | 100 | 110 | 1 | 20 | 2 |
TH0150-A-200V | 200 | 220 | 1 | 20 | 2 |
TH0150-A-300V | 300 | 330 | 1 | 20 | 2 |
TH0150-A-500V | 500 | 550 | 1 | 50 | 2 |
TH0150-A-600V | 600 | 660 | 1 | 50 | 2 |
TH0150-A-1000V | 1000 | 1100 | 1 | 50 | 2 |
Spezifikation | AC/DC-Differenz ( ppm ) | Phasenverschiebung ( μrad ) | ||||||
53 Hz | 1 kHz | 10 kHz | 100 kHz | 53 Hz | 1 kHz | 10 kHz | 100 kHz | |
TH0150-A-10V | 5 | 20 | 30 | 50 | 2 | 5 | 50 | 500 |
TH0150-A-20V | 7 | 20 | 30 | 60 | 2 | 8 | 60 | 750 |
TH0150-A-50V | 7 | 20 | 30 | 60 | 2 | 8 | 80 | 900 |
TH0150-A-100V | 9 | 20 | 30 | 100 | 4 | 15 | 120 | 1000 |
TH0150-A-200V | 9 | 20 | 40 | 150 | 4 | 15 | 150 | 1500 |
TH0150-A-300V | 9 | 20 | 40 | 200 | 4 | 15 | 200 | 1500 |
TH0150-A-500V | 10 | 30 | 60 | 250 | 5 | 15 | 250 | 2000 |
TH0150-A-600V | 10 | 40 | 80 | 300 | 5 | 20 | 300 | 2500 |
TH0150-A-1000V | 10 | 50 | 100 | 500 | 5 | 25 | 500 | 5000 |
Hinweis: Der Messwert des ACV ist nach folgender Formel zu berechnen: |
Spezifikation und Modell | Nenneingangsspannung ( V ) | Maximale Eingangsspannung ( V ) | Nennausgangsspannung ( V ) | Proportionale Unsicherheit ( k=2, ppm ) | Temperaturkoeffizient ( ppm/K ) |
TH0150-B-10V | 10 | 20 | 1 | 50 | 2 |
TH0150-B-20V | 20 | 30 | 1 | 50 | 2 |
TH0150-B-50V | 50 | 60 | 1 | 50 | 2 |
TH0150-B-100V | 100 | 110 | 1 | 50 | 2 |
TH0150-B-200V | 200 | 220 | 1 | 50 | 2 |
TH0150-B-300V | 300 | 330 | 1 | 50 | 2 |
TH0150-B-500V | 500 | 550 | 1 | 50 | 2 |
TH0150-B-600V | 600 | 660 | 1 | 50 | 2 |
TH0150-B-1000V | 1000 | 1100 | 1 | 50 | 2 |
Spezifikation | AC/DC-Differenz ( ppm ) | Phasenverschiebung ( μrad ) | ||||||
53 Hz | 1 kHz | 10 kHz | 100 kHz | 53 Hz | 1 kHz | 10 kHz | 100 kHz | |
TH0150-B-10V | 10 | 20 | 30 | 50 | 3 | 5 | 50 | 500 |
TH0150-B-20V | 10 | 20 | 30 | 60 | 3 | 8 | 60 | 750 |
TH0150-B-50V | 10 | 20 | 30 | 60 | 3 | 8 | 80 | 900 |
TH0150-B-100V | 10 | 20 | 30 | 100 | 5 | 15 | 120 | 1000 |
TH0150-B-200V | 10 | 20 | 40 | 150 | 5 | 15 | 150 | 1500 |
TH0150-B-300V | 10 | 20 | 40 | 200 | 5 | 15 | 200 | 1500 |
TH0150-B-500V | 10 | 30 | 60 | 250 | 5 | 15 | 250 | 2000 |
TH0150-B-600V | 10 | 40 | 80 | 300 | 5 | 20 | 300 | 2500 |
TH0150-B-1000V | 10 | 50 | 100 | 500 | 6 | 25 | 500 | 5000 |
Hinweis: Der Messwert des ACV ist nach folgender Formel zu berechnen: |
Stromversorgung | Typ TH0150-A: Passiv Typ TH0150-B: Lithium-Batterie |
Aufwärmzeit | 30 Minuten |
Temperaturleistung | Betriebstemperatur: 5~45 Grad; Kalibriertemperatur: 18~28 Grad; Lagertemperatur: -10~55 Grad Hinweis: Bei Lagerung in einer Umgebung mit rauen Temperaturen kann sich der Widerstandswert vorübergehend ändern und innerhalb der folgenden 30 Tage auf den ursprünglichen Widerstandswert zurückgesetzt werden. |
Feuchtigkeitsleistung | Luftfeuchtigkeit bei Betrieb: < % @ 30 < C, 70 % @ 40 < C, 40 % @ 50 80 C. Luftfeuchtigkeit bei Lagerung: ( 20%~80% ) R·H, nicht kondensierend |
Gewicht | 5 kg |
Verbindungsmodus | Eingang: Typ-N-Buchse, Ausgang: Stecker Typ N |
Gesamtabmessungen |
Lieferanten mit verifizierten Geschäftslizenzen