Grundlegende Informationen.
Modell Nr.
Fire Resistant LSOH Sheathed Cables
Conductor Material
Copper
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CE, CCC, RoHS, VDE
Produktbeschreibung
APPLICATION
The cables are designed for RS485 data connections where continued functionality is required during a fire situation. This cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.
STANDARDS
Basic design to EIA/TIA 485
FIRE PERFORMANCE
Circuit Integrity | IEC 60331-23 |
Flame Retardance (Single Vertical Wire Test) | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
Reduced Fire Propagation (Vertically-mounted bundled wires & cable test) | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Halogen Free | IEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1; BS 6425-1* |
No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2; BS 6425-2* |
Minimum Smoke Emission | IEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2* |
No Toxic gases | NES 02-713; NF C 20-454 |
Note: Asterisk * denotes superseded standard.
CABLE CONSTRUCTION
Multipair RS 485 Overall Screened Databus Cable
Conductors | Bare or tinned copper wire, stranded according to IEC 60228 class 2 |
Insulation | PE or fluoropolymer(FEP) compound |
Individual Fire Barrier | Fire resistant tape wrapped around the individual pairs or core assembly |
Cabling Elements | Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation |
Cabling | Pairs are cabled together in concentric layers |
Overall screen | Aluminum/polyester tape with tinned copper drain wire |
Overall Fire Barrier | Fire resistant tape wrapped core assembly |
Sheath | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option |
Multipair RS 485 Overall Double Screened Databus Cable
Conductors | Bare or tinned copper wire, stranded according to IEC 60228 class 2 |
Insulation | PE or fluoropolymer(FEP) compound |
Fire Barrier | Fire resistant tape wrapped around the individual pairs or core assembly |
Cabling Elements | Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation |
Cabling | Pairs are cabled together in concentric layers |
Overall screen | Aluminium/polyester tape plus copper wire braid |
Sheath | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option |
Multipair RS 485 Individual & Overall screened Databus Cable
Conductors | Bare or tinned copper wire, stranded according to IEC 60228 class 2 |
Insulation | PE or fluoropolymer(FEP) compound |
Fire Barrier | Fire resistant tape wrapped around the individual pairs or core assembly |
Cabling Elements | Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation |
Cabling | Pairs are cabled together in concentric layers |
Overall screen | Copper wire braid |
Sheath | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option |
Multipair RS 485 Overall Screened Databus Cable
Conductors | Bare or tinned copper wire, stranded according to IEC 60228 class 2 |
Insulation | PE or fluoropolymer(FEP) compound |
Fire Barrier | Fire resistant tape wrapped around the individual pairs or core assembly |
Cabling Elements | Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk. Two pair cable had four cores laid in quad formation |
Cabling | Pairs are cabled together in concentric layers |
Overall screen | Copper wire braid |
Sheath | Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.) . UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option |
PHYSICAL AND THERMAL PROPERTIES
Temperature range during operation (fixed state) | -20°C - +90°C |
Temperature range during installation (mobile state) | -5°C - +60°C |
Minimum bending radius | 8 x Overall Diameter |
ELECTRICAL PROPERTIES
DIELECTRIC TEST | 1000 V r.m.s. for 5' (core-core) |
| 1000 V r.m.s. for 5' (core-screen) |
IMPEDANCE | 120 Ω |
CAPACITANCE | 45 NF/km conductor to conductor |
| 90 NF/km conductor to shield |
CONSTRUCTION PARAMETERS
Multipair RS 485 Overall Screened Databus Cable
RE-m02Y(St)H-FR / RE-m02YS (St)H-FR / RE-m6YS (St)H-FR
AWG | No.of pair x2× Nominal Cross Sectional Area | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
---|
| mm2 | No/mm | mm | mm | mm | kg/km |
---|
24AWG | 1×2×0.22 | 7/0.2 | 0.6 | 0.40 | 4.6 | 29 |
24AWG | 2×2×0.22 | 7/0.2 | 0.6 | 0.40 | 8.1 | 60 |
24AWG | 4×2×0.22 | 7/0.2 | 0.6 | 0.40 | 9.6 | 100 |
22AWG | 1×2×0.50 | 16/0.2 | 0.8 | 0.50 | 5.2 | 44 |
22AWG | 2×2×0.50 | 16/0.2 | 0.8 | 0.50 | 9.3 | 91 |
22AWG | 4×2×0.50 | 16/0.2 | 0.8 | 0.50 | 11.1 | 158 |
18AWG | 1×2×0.75 | 24/0.2 | 1.0 | 0.60 | 5.6 | 56 |
18AWG | 2×2×0.75 | 24/0.2 | 1.0 | 0.60 | 10.3 | 117 |
18AWG | 4×2×0.75 | 24/0.2 | 1.0 | 0.60 | 12.2 | 207 |
16AWG | 1×2×1.00 | 30/0.2 | 1.2 | 0.80 | 5.8 | 61.4 |
16AWG | 2×2×1.00 | 30/0.2 | 1.2 | 0.80 | 10.6 | 128 |
16AWG | 4×2×1.00 | 30/0.2 | 1.2 | 0.80 | 12.5 | 228 |
Multipair RS 485 Overall Double Screened Databus Cable
RE-m02Y(St)CH-FR / RE-m02YS (St)CH-FR/ RE-m6YS (St)CH-FR
AWG | No.of pair x2× Nominal Cross Sectional Area | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
---|
| mm2 | No/mm | mm | mm | mm | kg/km |
---|
24AWG | 1×2×0.22 | 7/0.2 | 0.6 | 0.40 | 5.0 | 45 |
24AWG | 2×2×0.22 | 7/0.2 | 0.6 | 0.40 | 8.6 | 88 |
24AWG | 4×2×0.22 | 7/0.2 | 0.6 | 0.40 | 10.1 | 134 |
22AWG | 1×2×0.50 | 16/0.2 | 0.8 | 0.50 | 5.6 | 61 |
22AWG | 2×2×0.50 | 16/0.2 | 0.8 | 0.50 | 9.8 | 124 |
22AWG | 4×2×0.50 | 16/0.2 | 0.8 | 0.50 | 11.5 | 197 |
18AWG | 1×2×0.75 | 24/0.2 | 1.0 | 0.60 | 6.1 | 75 |
18AWG | 2×2×0.75 | 24/0.2 | 1.0 | 0.60 | 10.7 | 154 |
18AWG | 4×2×0.75 | 24/0.2 | 1.0 | 0.60 | 12.7 | 250 |
16AWG | 1×2×1.00 | 32/0.2 | 1.2 | 0.80 | 6.3 | 81 |
16AWG | 2×2×1.00 | 32/0.2 | 1.2 | 0.80 | 11.0 | 166 |
16AWG | 4×2×1.00 | 32/0.2 | 1.2 | 0.80 | 13.0 | 273 |
Multipair RS 485 Individual & Overall screened Databus Cable
RE-m02Y(St)H pimf-FR / RE-m02YS (St)H pimf -FR / RE-m6YS (St)H pimf-FR
AWG | No.of pair x2× Nominal Cross Sectional Area | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
---|
| mm2 | No/mm | mm | mm | mm | kg/km |
---|
24AWG | 1×2×0.22 | 7/0.2 | 0.6 | 0.40 | 4.9 | 46 |
24AWG | 2×2×0.22 | 7/0.2 | 0.6 | 0.40 | 8.6 | 91 |
24AWG | 4×2×0.22 | 7/0.2 | 0.6 | 0.40 | 10.1 | 144 |
22AWG | 1×2×0.50 | 16/0.2 | 0.8 | 0.50 | 5.5 | 62 |
22AWG | 2×2×0.50 | 16/0.2 | 0.8 | 0.50 | 9.8 | 127 |
22AWG | 4×2×0.50 | 16/0.2 | 0.8 | 0.50 | 11.6 | 209 |
18AWG | 1×2×0.75 | 24/0.2 | 1.0 | 0.60 | 6.0 | 76 |
18AWG | 2×2×0.75 | 24/0.2 | 1.0 | 0.60 | 10.7 | 157 |
18AWG | 4×2×0.75 | 24/0.2 | 1.0 | 0.60 | 12.7 | 263 |
16AWG | 1×2×1.00 | 32/0.2 | 1.2 | 0.80 | 6.2 | 83 |
16AWG | 2×2×1.00 | 32/0.2 | 1.2 | 0.80 | 11.0 | 170 |
16AWG | 4×2×1.00 | 32/0.2 | 1.2 | 0.80 | 13.0 | 286 |
Multipair RS 485 Overall Screened Databus Cable
RE-m02YCH-FR / RE-m02YS CH-FR/ RE-m6YS CH-FR
AWG | No.of pair x2× Nominal Cross Sectional Area | No./Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Sheath Thickness | Nominal Overall Diameter | Approx. Weight |
---|
| mm2 | No/mm | mm | mm | mm | kg/km |
---|
24AWG | 1×2×0.22 | 7/0.2 | 0.6 | 0.40 | 4.8 | 41 |
24AWG | 2×2×0.22 | 7/0.2 | 0.6 | 0.40 | 8.4 | 82 |
24AWG | 4×2×0.22 | 7/0.2 | 0.6 | 0.40 | 9.9 | 127 |
22AWG | 1×2×0.50 | 16/0.2 | 0.8 | 0.50 | 5.4 | 57 |
22AWG | 2×2×0.50 | 16/0.2 | 0.8 | 0.50 | 9.6 | 117 |
22AWG | 4×2×0.50 | 16/0.2 | 0.8 | 0.50 | 11.4 | 189 |
18AWG | 1×2×0.75 | 24/0.2 | 1.0 | 0.60 | 5.9 | 71 |
18AWG | 2×2×0.75 | 24/0.2 | 1.0 | 0.60 | 10.5 | 146 |
18AWG | 4×2×0.75 | 24/0.2 | 1.0 | 0.60 | 12.4 | 241 |
16AWG | 1×2×1.00 | 32/0.2 | 1.2 | 0.80 | 6.0 | 77 |
16AWG | 2×2×1.00 | 32/0.2 | 1.2 | 0.80 | 10.8 | 158 |
16AWG | 4×2×1.00 | 32/0.2 | 1.2 | 0.80 | 12.8 | 264 |
Die Anschrift:
Room3501, Citic Square, 1168nanjing Xi Lu, 200041, Shanghai, China
Unternehmensart:
Hersteller/Werk
Geschäftsbereich:
Elektronik
Firmenvorstellung:
Addison Verkabelungssystem, entstanden als Netzwerk-Verkabelungssystem-Lösung von Caledonian Cables Ltd in Sussex, England vermarktet. Caledonian Cable wurde 1978 gegründet und trat ursprünglich als OEM-Hersteller von Verkabelungssystemen auf den Markt.
Bis 1990s war Caledonian ausschließlich ein Kabel-OEM-Hersteller und Patchcord-Vorkonfektionär für die renommierten Kabelunternehmen in Europa.
1997 trat Caledonian mit Komplettlösungen unter der Marke Addison für die Twisted-Pair-Netzwerkumgebung in den Markt für Datenverkabelungen ein. 1998 entwickelte sich Caledonian zu einem der vielversprechenden Hersteller von OEM-Verkabelungslösungen in Europa.
Addison OMS Network Cabling System besteht aus horizontalem Netzwerkkabelsystem, vertikalem Netzwerkkabelsystem, Backbone-Netzwerkkabelsystem und Work Area Network Cabling System usw.