Application: | LAN Cable |
---|---|
Conductor Material: | BC/CCS/CCA/TC/CU/CCAG |
Cover Material: | PVC |
Type: | Cat 5 |
Material Shape: | Round Wire |
Conductor Type: | Solid |
Lieferanten mit verifizierten Geschäftslizenzen
Teststandard | ANSI/TIA-568-C,2,ISO/ IEC 11801,IEC 61156,BS EN 50288 | ||||||||||
Physikalische Parameter | |||||||||||
Leiter | Material | Reines Kupfer | |||||||||
Durchmesser (mm) | 0,500±0,005 | ||||||||||
Isolierung | Material | HDPE | |||||||||
Durchmesser (mm) | 0,89±0,05 | ||||||||||
Kernfarbe | 1.weiß-blau/blau | 2.weiß-orange/orange | |||||||||
3.weiß-grün/grün | 4.weiß-braun/braun | ||||||||||
Ummantelung | Material | PVC/LSZH | |||||||||
Dicke (mm) | 0,55±0,05 | ||||||||||
Durchmesser (mm) | 5,2 ±0,3 | ||||||||||
Farbe | Optional | ||||||||||
Oberflächendruck | Letter hoch (mm) | 3,0 ± 0,5 | |||||||||
Farbe | Schwarz/Weiß | ||||||||||
Druckfehler und Speicherplatz | ≤± 0,5% ,1m | ||||||||||
Elektrische Parameter | |||||||||||
Leiterwiderstand (20ºC) | ≤9,38 Ω/ 100m | ||||||||||
Elektrischer Widerstand Unsymmetrie ( 20ºC) | ≤2,5 % | ||||||||||
Isolationswiderstand | >5000 MΩ·km | ||||||||||
Unsymmetrie der Kapazität zwischen Paar und Erde (0,8 kHz oder 1KHz) | ≤160 pF/100m | ||||||||||
Gegenseitige Kapazität eines Paares | ≤5,6nF/100m | ||||||||||
Technische Leistung | |||||||||||
Feq MHZ |
Zin | IL | RL | WEITER | PS NEXT | ELFEXT | PS ELFEXT | ||||
Ω | DB/100m | DB | DB/100m | DB/100m | DB/100m | DB/100m | |||||
1,0 | 100±15 | ≤2,04 | ≥20,0 | ≥65,30 | ≥62,30 | ≥64,00 | ≥61,00 | ||||
4,0 | ≤4,05 | ≥23,0 | ≥56,27 | ≥53,27 | ≥51,96 | ≥48,96 | |||||
8,0 | ≤5,77 | ≥24,5 | ≥51,75 | ≥48,75 | ≥45,94 | ≥42,94 | |||||
10,0 | ≤6,47 | ≥25,0 | ≥50,30 | ≥47,30 | ≥44,00 | ≥41,00 | |||||
16,0 | ≤8,25 | ≥25,0 | ≥47,24 | ≥44,24 | ≥39,92 | ≥36,92 | |||||
25,0 | ≤10,42 | ≥24,3 | ≥44,3 | ≥41,30 | ≥36,00 | ≥33,12 | |||||
31,25 | ≤11,71 | ≥23,6 | ≥42,89 | ≥39,89 | ≥34,12 | ≥31,12 | |||||
62,5 | ≤16,99 | ≥21,5 | ≥38,36 | ≥35,36 | ≥28,08 | ≥25,08 | |||||
100 | ≤21,98 | ≥20,1 | ≥35,30 | ≥32,30 | ≥24,00 | ≥21,00 | |||||
Umgebungstemperatur | |||||||||||
Speichern | 0~40ºC | Arbeit | -20 ~ 60ºC | ||||||||
Anmerkung | |||||||||||
A) das Kabel kann den fluke Test bestehen. b) der Außendurchmesser der Isolierung und der Außendurchmesser der Ummantelung dienen nur als Referenz. |
Lieferanten mit verifizierten Geschäftslizenzen