Grundlegende Informationen.
Modell Nr.
3HP/5HP/8HP/10HP/15HP/20HP/25HP
Verwenden Natur
Produktion
Bescheinigung
RoHS, CE, SGS
Produktbeschreibung
Electrophoresis special refrigeration equipment (1) chiller transportation moving should make the necessary protective measures, rainproof bull. (2) machine in handling process, loading and unloading car should be light, avoid touch attack. Second, the machine is installed (1) the machine should be installed in the well ventilated, dry, no air pollution, and environmental temperature, no more than 45 ° indoor, installation position to balance.(2) the in-out water chillers, circulation cooling water pipes, matching correctly, reasonable design, reasonable design connection not leak.(3) from surrounding walls refrigerating not less than 45CM blockage. Third, the power connector (1) the machine adopts three-phase four-wire, power, (R, S, T) 380V power lines (N), and meet up neutral grounding wire connection "correct".(2) the power generator voltage: 380V ± 10%. Electricity frequently rate: isolator ± 2%(3) power supply voltage fluctuation, cannot start the machine transducer, such as forced open machines to bring the machine, the company does not damage the responsibility.(4) control of the machine, the electrical appliances chain circuit arbitrarily change, it shall be the client needs to change in the company, the company, or until after checking contents alter line again, otherwise, the company inform the client does not bear the consequences of after the changes. Four, the machine operation (1) before starting around carefully check whether there is abnormal, wire connection, whether it is right, tighten conduit installation is correct, the voltage is normal.(2) open valve, check automatic water chillers tank has been filled with water (whether to check the cooling tower, water pump, water condenser circulating system until the water full without water or water do not run).(3) turn on the power switch, watch the lights on the panel, and display, pump has a thermometer on the job, and the thermometer, little also host to delay 4 minutes on it again. Five, temperature adjustment Operational guidelinesThe lights on the thermometer from top to bottom of the table meaning function: Bright lights flashingTemperature limit set limit temperatureLower temperature limit temperature settingemptyRefrigeration compressor boot is protected. Delay How to set upper temperature?At the same time in two key, enter temperature limit state, digital display Settings display temperature to limit temperature (" thickening 0.1 ° c ", "button 0.1 ° c," button to reduce down more than 0.5 seconds is quick put reduced). After the completion of the upper temperature setting, and according to the key to store the data. According to the same methods set temperature limit. Note that "> upper limit controller this rule.Note: 1, in the status, if not connected 5 seconds, automatic exit status.2, the heart must exit status to ensure that data will be stored. If the electricity, didn't quit before setting value may not be preserved.* basic working principletemperature control Temperature control according to the "upper" and "lower temperature, temperature" two parameters hypotheses "limit for 20 degrees Celsius temperature", "lower temperature" for 18 degrees Celsius, when the temperature control of temperature probe on perceived than 20 ° c j-t until the temperature is below 18 degrees temperature control, will stop refrigeration in 18 degrees - 20 ° c.When the extended compressor bootThere is a "controller", when the timer compressor stop timing starts when stop compressor, the first check before starting compressor, if has the timer with four minutes to start compressor, if dissatisfied with four minutes as four minutes is restarted. This can be restarted after stopping guarantee interval 4 minutes, prevent frequently damage compressor.Another controller of electricity within four minutes, just won't start compressor, this call again in electricity situation also can protect the compressor. (note: compressor in the time when extended protection on the above assumptions, adjustable Settings for four minutes). 6 and failure analysis, and simple questions processing method (1) panel indicatorName state processing method Phase failureLight (1) the power supply voltage is not normal, or the power of a photograph investigations(2) the power R, S, T sequence of two lines, exchange of position System fault not bright says input circuit is normal Bright, ventilated and undesirable heat that should check whether the machine is water-cooled (the obstacles to check, cooling tower, water pump, not the condenser circulating system is normal operation thereof, according to the problems after) inside the machine pressure switch (two little red dot) reset. Host system fault not light Light (1) from ac contactor to check whether the power cord connecting main compressor normal (2) host has damaged (please check technicians specialized refrigeration), Pump failureLight (1) for a long time when the pump's live (for supplemental pump start-up),(2) host water pump has been damaged, replace or pump. A host running on normal workDon't light didn't boot, or control in delay Note: if the equipment failure, please press the check cannot be excluded, if the company or professional please contact: no refrigeration technician experience cut from further loss. Seven, the daily maintenance and maintenance (1) every time before starting the check whether there is abnormal things around letter voltage, water pump, water pipe flow, whether there is water, cooling water circulation outside is normal or not.(2) chiller every operation period, usually two to three months, according to the heat transfer air-filled type to clean, water-cooled to clean with clear water cooling towers.(3) annually to do a big maintenance, do a machine maintenance and cleaning up.(4) advice in a professional technicians with refrigeration equipment maintenance etc.Electrophoresis special refrigeration equipment A machine (1) chiller transportation moving should make the necessary protective measures, rainproof bull. (2) machine in handling process, loading and unloading car should be light, avoid touch attack. Second, the machine is installed (1) the machine should be installed in the well ventilated, dry, no air pollution, and environmental temperature, no more than 45 ° indoor, installation position to balance.(2) the in-out water chillers, circulation cooling water pipes, matching correctly, reasonable design, reasonable design connection not leak.(3) from surrounding walls refrigerating not less than 45CM blockage. Third, the power connector (1) the machine adopts three-phase four-wire, power, (R, S, T) 380V power lines (N), and meet up neutral grounding wire connection "correct".(2) the power generator voltage: 380V ± 10%. Electricity frequently rate: isolator ± 2%(3) power supply voltage fluctuation, cannot start the machine transducer, such as forced open machines to bring the machine, the company does not damage the responsibility.(4) control of the machine, the electrical appliances chain circuit arbitrarily change, it shall be the client needs to change in the company, the company, or until after checking contents alter line again, otherwise, the company inform the client does not bear the consequences of after the changes. Four, the machine operation (1) before starting around carefully check whether there is abnormal, wire connection, whether it is right, tighten conduit installation is correct, the voltage is normal.(2) open valve, check automatic water chillers tank has been filled with water (whether to check the cooling tower, water pump, water condenser circulating system until the water full without water or water do not run).(3) turn on the power switch, watch the lights on the panel, and display, pump has a thermometer on the job, and the thermometer, little also host to delay 4 minutes on it again. Five, temperature adjustment Operational guidelinesThe lights on the thermometer from top to bottom of the table meaning function: Bright lights flashingTemperature limit set limit temperatureLower temperature limit temperature settingemptyRefrigeration compressor boot is protected. Delay How to set upper temperature?At the same time in two key, enter temperature limit state, digital display Settings display temperature to limit temperature (" thickening 0.1 ° c ", "button 0.1 ° c," button to reduce down more than 0.5 seconds is quick put reduced). After the completion of the upper temperature setting, and according to the key to store the data. According to the same methods set temperature limit. Note that "> upper limit controller this rule.Note: 1, in the status, if not connected 5 seconds, automatic exit status.2, the heart must exit status to ensure that data will be stored. If the electricity, didn't quit before setting value may not be preserved.* basic working principletemperature control Temperature control according to the "upper" and "lower temperature, temperature" two parameters hypotheses "limit for 20 degrees Celsius temperature", "lower temperature" for 18 degrees Celsius, when the temperature control of temperature probe on perceived than 20 ° c j-t until the temperature is below 18 degrees temperature control, will stop refrigeration in 18 degrees - 20 ° c.When the extended compressor bootThere is a "controller", when the timer compressor stop timing starts when stop compressor, the first check before starting compressor, if has the timer with four minutes to start compressor, if dissatisfied with four minutes as four minutes is restarted. This can be restarted after stopping guarantee interval 4 minutes, prevent frequently damage compressor.Another controller of electricity within four minutes, just won't start compressor, this call again in electricity situation also can protect the compressor. (note: compressor in the time when extended protection on the above assumptions, adjustable Settings for four minutes). 6 and failure analysis, and simple questions processing method (1) panel indicatorName state processing method Phase failureLight (1) the power supply voltage is not normal, or the power of a photograph investigations(2) the power R, S, T sequence of two lines, exchange of position System fault not bright says input circuit is normal Bright, ventilated and undesirable heat that should check whether the machine is water-cooled (the obstacles to check, cooling tower, water pump, not the condenser circulating system is normal operation thereof, according to the problems after) inside the machine pressure switch (two little red dot) reset. Host system fault not light Light (1) from ac contactor to check whether the power cord connecting main compressor normal (2) host has damaged (please check technicians specialized refrigeration), Pump failureLight (1) for a long time when the pump's live (for supplemental pump start-up),(2) host water pump has been damaged, replace or pump. A host running on normal workDon't light didn't boot, or control in delay Note: if the equipment failure, please press the check cannot be excluded, if the company or professional please contact: no refrigeration technician experience cut from further loss. Seven, the daily maintenance and maintenance (1) every time before starting the check whether there is abnormal things around letter voltage, water pump, water pipe flow, whether there is water, cooling water circulation outside is normal or not.(2) chiller every operation period, usually two to three months, according to the heat transfer air-filled type to clean, water-cooled to clean with clear water cooling towers.(3) annually to do a big maintenance, do a machine maintenance and cleaning up.(4) advice in a professional technicians with refrigeration equipment maintenance etc.
Die Anschrift:
Building 3, Furong Xinda Technology Park, Shajing Town, Baoan District, Shenzhen
Unternehmensart:
Hersteller/Werk
Geschäftsbereich:
Auto, Motor und Zusatz, Chemische Produkte, Elektronik, Industrielle Anlagen und Zusatzteile, Produktionsmaschinen, Spielzeug, Sport und Erholung
Zertifizierung des Managementsystems:
ISO 9001
Firmenvorstellung:
Shenzhen Yuehuihuang Automation Equipment Co., Ltd ist eine professionelle Herstellung von elektrophoretischen Beschichtung, spezialisiert in der Herstellung elektrophoretische Beschichtung mehr als zehn Jahre, die sich zum besten Marktführer in elektrophoretischen Beschichtungsbereichen und einer der besten elektrophoretischen Beschichtungsanlagen Unternehmen. Unser Unternehmen hat ein Grundkapital von 500 Millionen, mit mehr als 70 professionellen Menschen, die im Ausland langfristig zu arbeiten. Unsere Produkte werden in Südkorea, Vietnam, Russland und mehr als 10 Länder und Regionen vertrieben. YueHuiHuang bieten die erstklassigen Produkte, Qualität und Service, streng nach ISO9001. Bieten Sie dem Kunden einen Service aus einer Hand, z. B. Auswahl des Modells von Elektrophoresegeräten, Planung, Design, Installation, Debugging, Optionierung von elektrophoretischen Beschichtungen, Proofing und Trainingstechnik.
Unser Unternehmen Hauptsitz der Herstellung von Ausrüstung befindet sich in der Provinz Guangdong und die Malerei Herstellung befindet sich in der Provinz Zhejiang. Das Unternehmen verfügt über ein komplettes After-Sales-Netzwerk und in den kundenintensiven Bereichen wie Guangzhou Panyu, Shandong Weifang, Liaoning Shenyang, Zhejiang Wenzhou, Henan Zhengzhou, Luoyang, Shaanxi Xi′an, Hebei Shijiazhuang Xinle, Hunan Shaodong, sichuan Chengdu, Sind mit Kundendienststellen oder untergeordneten Zweigstellen ausgestattet, die sich verpflichten, die Probleme des Kunden in kurzer Zeit zu lösen. Derzeit ist unser Unternehmen nicht nur Service in China, sondern auch in Übersee.
Unser Vorteil: Wir erleben eine Vielzahl von Engineering-Fällen und basierend auf der Zusammenfassung weiterhin entwickeln und verbessern alle Zusatzgeräte nach den Anforderungen des Kunden und um alle unabhängigen Produktion zu erreichen. Wir verpflichten uns, alle Probleme, die sich aus dem Prozess der Nutzung der Kunden für die Ausrüstung und Beschichtung ist die Herstellung von uns zu lösen.
Unsere Bereiche: Nach vielen Jahren harter Arbeit und Übung haben wir entscheidende technologische Durchbrüche in der Sägeblattelektrophorese und Radausrichtung geschafft. Die von uns geplante und konzipierte Ausrüstung, die Sägeblatt- und Nabenumrüstung durch fortschrittliche Elektrophorese werden von Kunden im in- und Ausland gelobt. Gleichzeitig in der Auto-Teile, Landmaschinen, Dreirad, leichte LKW, spezielle Fahrzeug Tür-und Fensterdekoration, Motoren und andere Hardware-Zubehör-Industrie hat eine ausgezeichnete Leistung und hat viele erfolgreiche Fälle in der entsprechenden Industrie Benchmarking Unternehmen.
Unsere Ideen: Wir streben nach Qualität und Innovation in unseren Produkten, ständig neue und hohe Wissenschaft und Technologie einzuführen, stärken die Unternehmensführung, verbessern die Personalschulung, Qualitätskontrolldaten, perfektes Designkonzept, hohe Qualität Pre-Sale, Verkauf, Der Kundendienst. Unternehmen halten die Unternehmensphilosophie der "wissenschaftlichen und technologischen Innovation, Exzellenz, nachhaltige Entwicklung, guten Glauben Service"