Grundlegende Informationen.
Leitertyp
Solid & Stranded
Anwendung
Power Distribution Networks
Leitermaterial
Aluminum Alloy Conductor
Anwendungsbereiche
Power Distribution Networks
Bescheinigung
ISO9001, CCC
Armoured Layer
Interlocked Armoured
Produktbeschreibung
APPLICATION
YJLH92-Aluminum Alloy Conductor XLPE Insulated Interlocked Armoured PVC Sheathed Power Cable.
This product is suitable for using in power distribution networks or fixed installations for industrial equipments with rated voltage up to and including 26/35KV
BASIC INFORMATION
1. Code Name
YJLH92
2. Rated Voltage (Uo/U)
0.6/1KV
3. Cable Structure
Aluminum Alloy Conductor/XLPE Insulation/Interlocked Armoured/PVC Sheath
CONSTRUCTION
Conductor
Number of conductors:2,3,4,5
The conductors shall comply with the requirement given in IEC
Insulation
XLPE(Cross-linked Polyethylene) according to IEC
Armoured Layer
Interlocked Armoured
Outer Sheath
PVC(Polyethylene Chloride)according to IEC
CABLE STANDARDS
GB/T12706-2008,IEC,BS,ASTM and etc. upon request.
CHARACTERISTICS
1. Conductor temperature
Maximum conductor temperature in normal use: 90ºC
2. Max.short-circuit temperature
Maximum shall not exceed 250ºC(5s Max,Duration)
3. Installation temperature
Ambient temperature under installation shall not be below 0ºC
4. Minimum bending radius
The bending radius of cable: (D-Diameter of cable)
-------------------------------------≥7D
Voltage designation
The rated voltage of the cable for a given application shall be suitable for the operating conditions in the system in which the cable is used,and is expressed in the form of Uo/ U(Um)kV.
Where:
Uo-The rated power-frequency voltage between conductor and screen or metallic-sheath,for which the cable designed;
U-The rated power-frequency voltage between conductors, for which the cable designed:
Urn-The maximum value of the "hight system voltage " for which the equipment may he operated.
Rated voltaged of cable applied in three phrase system are given in table
U | Um | Uo |
First class | Second class |
1 | 1.2 | 0.6 | 0.6 |
3 | 3.6 | 1.8 | 3.6 |
6 | 7.2 | 3.6 | 6 |
10 | 12 | 6 | 8.7 |
15 | 17.5 | 8.7 | 12 |
20 | 24 | 12 | 18 |
35 | 42 | 21 | 26 |
Note:The first class cable suitable for one single-phrase earth-fault time does not exceed 1 min each time and Max. time not exceed 8 hours.and not exceed 125 hours in all in one year.
The second class cable suitable fir more earth-fault time and more better insulation performance.
Production Range of cable
Type | No. of cores | Nominal Cross sectional area m2 |
Aluminum alloy conductor |
YJLH92 | 2 | 4-300 |
3 | 4-630 |
4 | 4-500 |
3+1 | 4-630 |
5 | 4-500 |
4+1 | 4-500 |
3+2 | 4-500 |
*The armoured single-core cables are used for D.C system only. As for A.C system non-magnetic armoured material should be used. Or magnetic isolation measures should be applied. |
DIMENSIONS-YJLH92-Table 01
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
2×10 | 0.7 | 18.5 | 302 |
2×16 | 0.7 | 20.5 | 371 |
2×25 | 0.9 | 23.7 | 483 |
2×35 | 0.9 | 25.7 | 575 |
2×50* | 1.0 | 28.7 | 720 |
2×70* | 1.1 | 32.7 | 915 |
2×95* | 1.1 | 35.9 | 1122 |
2×120* | 1.2 | 40.1 | 1381 |
2×150* | 1.4 | 43.7 | 1644 |
2×185* | 1.6 | 48.3 | 1968 |
2×240* | 1.7 | 53.5 | 2433 |
2×300* | 1.8 | 58.5 | 2926 |
*Compacted conductor
DIMENSIONS-YJLH92 -Table 02
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
3×10 | 0.7 | 19.2 | 353 |
3×16 | 0.7 | 21.5 | 444 |
3×25 | 0.9 | 24.9 | 591 |
3×35 | 0.9 | 27.1 | 716 |
3×50* | 1.0 | 30.3 | 913 |
3×70* | 1.1 | 34.8 | 1190 |
3×95* | 1.1 | 38.4 | 1491 |
3×120* | 1.2 | 42.7 | 1823 |
3×150* | 1.4 | 46.6 | 2186 |
3×185* | 1.6 | 51.7 | 2654 |
3×240* | 1.7 | 57.1 | 3274 |
3×300* | 1.8 | 62.4 | 3955 |
3×400* | 2.0 | 70.4 | 5099 |
*Compacted conductor
DIMENSIONS-YJLH92 -Table 03
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
4×10 | 0.7 | 20.7 | 413 |
4×16 | 0.7 | 23.1 | 526 |
4×25 | 0.9 | 27.0 | 713 |
4×35 | 0.9 | 29.4 | 871 |
4×50* | 1.0 | 33.2 | 1139 |
4×70* | 1.1 | 38.2 | 1488 |
4×95* | 1.1 | 42.2 | 1873 |
4×120* | 1.2 | 47.0 | 2298 |
4×150* | 1.4 | 51.5 | 2787 |
4×185* | 1.6 | 57.0 | 3363 |
4×240* | 1.7 | 63.2 | 4191 |
4×300* | 1.8 | 69.2 | 5075 |
4×400* | 2.0 | 78.0 | 6553 |
*Compacted conductor
DIMENSIONS-YJLH92 -Table 04
Nominal cross sectional area of conductor(mm²) | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
5×10 | 0.7 | 22.2 | 475 |
5×16 | 0.7 | 24.9 | 612 |
5×25 | 0.9 | 29.2 | 836 |
5×35 | 0.9 | 32.1 | 1043 |
5×50* | 1.0 | 36.4 | 1371 |
5×70* | 1.1 | 41.9 | 1795 |
5×95* | 1.1 | 46.4 | 2265 |
5×120* | 1.2 | 51.9 | 2807 |
5×150* | 1.4 | 56.7 | 3381 |
5×185* | 1.6 | 63.0 | 4113 |
5×240* | 1.7 | 69.9 | 5132 |
5×300* | 1.8 | 76.7 | 6251 |
5×400* | 2.0 | 86.5 | 8073 |
*Compacted conductor
DIMENSIONS-YJLH92-Table 05
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
3x16+1x10 | 3 | 0.7 | 22.5 | 498 |
1 | 0.7 |
3x25+1x16 | 3 | 0.9 | 26.1 | 667 |
1 | 0.7 |
3x35+1x16 | 3 | 0.9 | 27.9 | 786 |
1 | 0.7 |
3x50+1x25 | 3* | 1.0 | 31.8 | 1037 |
1 | 0.9 |
3x70+1x35 | 3* | 1.1 | 36.0 | 1328 |
1 | 0.9 |
3x95+1x50 | 3* | 1.1 | 40.0 | 1687 |
1 | 1.0 |
3x120+1x70 | 3* | 1.2 | 44.8 | 2089 |
1 | 1.1 |
3x150+1x70 | 3* | 1.4 | 48.3 | 2464 |
1 | 1.1 |
3x185+1x95 | 3* | 1.6 | 53.4 | 3004 |
1 | 1.1 |
3x240+1x120 | 3* | 1.7 | 59.3 | 3739 |
1 | 1.2 |
3x300+1x150 | 3* | 1.8 | 64.9 | 4525 |
1 | 1.4 |
3x400+1x185 | 3* | 2.0 | 73.0 | 5793 |
1 | 1.6 |
*Compacted conductor
DIMENSIONS-YJLH92 -Table 06-A
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
4x16+1x10 | 4 | 0.7 | 25.0 | 594 |
1 | 0.7 |
4x25+1x16 | 4 | 0.9 | 29.4 | 808 |
1 | 0.7 |
4x35+1x16 | 4 | 0.9 | 32.1 | 970 |
1 | 0.7 |
4x50+1x25 | 4* | 1.0 | 36.6 | 1295 |
1 | 0.9 |
4x70+1x35 | 4* | 1.1 | 42.2 | 1690 |
1 | 0.9 |
1 | 1.6 |
*Compacted conductor
DIMENSIONS-YJLH92 -Table 06-B
4x95+1x50 | 4* | 1.1 | 46.5 | 2188 |
1 | 1.0 |
4x120+1x70 | 4* | 1.2 | 52.1 | 2639 |
1 | 1.1 |
4x150+1x70 | 4* | 1.4 | 56.9 | 3119 |
1 | 1.1 |
4x185+1x95 | 4* | 1.6 | 63.3 | 3830 |
1 | 1.1 |
4x240+1x120 | 4* | 1.7 | 70.3 | 4767 |
1 | 1.2 |
4x300+1x150 | 4* | 1.8 | 77.0 | 5769 |
1 | 1.4 |
4x400+1x185 | 4* | 2.0 | 87.0 | 7438 |
1 | 1.6 |
*Compacted conductor
DIMENSIONS-YJLH92 -Table 07
Nominal cross sectional area of conductor(mm²) | No.of cores | Nominal insulation thickness(mm) | YJLH92 |
Approx overall diameter(mm) | Cable weight max(kg/km) |
3x16+2x10 | 3 | 0.7 | 24.9 | 574 |
2 | 0.7 |
3x25+2x16 | 3 | 0.9 | 29.3 | 775 |
2 | 0.7 |
3x35+2x16 | 3 | 0.9 | 32.0 | 907 |
2 | 0.7 |
3x50+2x25 | 3* | 1.0 | 36.3 | 1198 |
2 | 0.9 |
3x70+2x35 | 3* | 1.1 | 41.9 | 1560 |
2 | 0.9 |
3x95+2x50 | 3* | 1.1 | 46.4 | 1984 |
2 | 1.0 |
3x120+2x70 | 3* | 1.2 | 51.8 | 2462 |
2 | 1.1 |
3x150+2x70 | 3* | 1.4 | 56.6 | 2847 |
2 | 1.1 |
3x185+2x95 | 3* | 1.6 | 63.0 | 3515 |
2 | 1.1 |
3x240+2x120 | 3* | 1.7 | 70.0 | 4364 |
2 | 1.2 |
3x300+2x150 | 3* | 1.8 | 76.7 | 5278 |
2 | 1.4 |
3x400+2x185 | 3* | 2.0 | 86.5 | 6717 |
2 | 1.6 |
*Compacted conductor
Product Data Of Cable
Nominal cross-sectional area of conductor(mm²) | Max.D.C resistance of conductor at 20ºC(Ω/km) |
Aluminum Alloy |
4 | 7.19 |
6 | 4.48 |
10 | 2.99 |
16 | 1.85 |
25 | 1.17 |
35 | 0.843 |
50 | 0.622 |
70 | 0.430 |
95 | 0.311 |
120 | 0.246 |
150 | 0.200 |
185 | 0.159 |
240 | 0.121 |
300 | 0.0971 |
400 | 0.0755 |
500 | 0.0587 |
630 | 0.0455 |
800 | 0.0356 |
Power frequency A.C. Voltage test | Test voltage 3.5kV/5 min |
Current carrying capacity of cable
In the air
Conductor | Nominal Cross sectional area of conductor mm2 | Armored cable |
Single Core | Two Core | Three cores & Five cores |
| |
Aluminum Alloy Conductor | 4 | 32 | 42 | - | - |
6 | 42 | 56 | - | - |
10 | 55 | 72 | 58 | 50 |
16 | 71 | 93 | 75 | 64 |
25 | 94 | 120 | 100 | 86 |
35 | 115 | 150 | 120 | 105 |
50 | 140 | 180 | 145 | 125 |
70 | 180 | 230 | 190 | 165 |
95 | 220 | 285 | 235 | 200 |
120 | 260 | 330 | 270 | 235 |
150 | 300 | 380 | 310 | 270 |
185 | 350 | 445 | 355 | 310 |
240 | 414 | 530 | - | 365 |
300 | 485 | 615 | - | 420 |
Aluminum Alloy Conductor | 400 | 570 | 720 | - | 495 |
500 | 670 | 850 | - | - |
630 | 790 | 1000 | - | - |
800 | 920 | 1180 | - | - |
Current carrying capacity of cable
In the ground
Conductor | Nominal Cross sectional area of conductor mm2 | Armored cable |
Single Core | Two Core | There cores Five cores |
| |
Aluminum alloy Conductor | 4 | 43 | 47 | 47 | 40 |
6 | 56 | 60 | 61 | 50 |
10 | 71 | 75 | 77 | 65 |
16 | 91 | 97 | 105 | 85 |
25 | 115 | 125 | 130 | 110 |
35 | 140 | 150 | 155 | 130 |
50 | 165 | 175 | 185 | 155 |
70 | 205 | 215 | 230 | 190 |
95 | 245 | 260 | 275 | 230 |
120 | 280 | 295 | 315 | 260 |
150 | 315 | 335 | 355 | 295 |
185 | 360 | 380 | 400 | 335 |
240 | 420 | 445 | - | 390 |
300 | 475 | 505 | - | 440 |
400 | 545 | 575 | - | 505 |
500 | 620 | 665 | - | - |
630 | 705 | 760 | - | - |
800 | 800 | 875 | - | - |
Installation and Operation Condition of Cable
In the air
1.The distance between two adjacent cable' axle centers of single-core cables laid in parallel cross-section area of conductor≤185mm²;2 times of the cable diameter cross-sectional area of conductor≥240mm²;90mm
2.Ambient air temperature:30ºC.
3.Max.continous operating temperature of conductor: 90ºC.
Current carrying rating factors for different ambient air temperature
Ambient air temperature | 20ºC | 25ºC | 30ºC | 35ºC | 40ºC | 45ºC |
Correction factor | 1.09 | 1.04 | 1.00 | 0.95 | 0.90 | 0.84 |
Directly in the ground
1.The single-core cables are installed separately.The distance between the cable
center is 2 times of the cable Diameter.
2.Soil temperature: 25ºC.
3.Max.continous operating temperature of
conductor: 90ºC.
4.Thermal resistivity of soil : 1.0 ºC. m/W
5.Depth of Direct-Buried:0.7m.
Current carrying rating factors for different soil temperature
Soil temperature | 20ºC | 25ºC | 30ºC | 35ºC | 40ºC |
Correction factor | 1.04 | 1.0 | 0.96 | 0.92 | 0.87 |
Die Anschrift:
Room1116, Floor 11, Hongxing Jiuzhou International Plaza, Xincheng Road, Yixing, Wuxi, Jiangsu, China
Unternehmensart:
Hersteller/Werk, Handelsunternehmen
Geschäftsbereich:
Chemische Produkte, Elektronik, Service
Zertifizierung des Managementsystems:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001
Firmenvorstellung:
Lonheo wurde 2014 gegründet und vereint die Fabrik mit mehr als 30 Jahren Erfahrung im Kabelbetrieb. Lonheo wird durch den ausgezeichneten Ruf unserer kooperierten Fabrik unterstützt. Alles, was wir tun, ist, sie zu führenden Kabelunternehmen der Welt zu machen.
Lonheo ist in der Lage, im heutigen wettbewerbsorientierten Geschäftsumfeld durch die Schaffung von Synergie und die Konsolidierung der Ressourcen aller Partner zu streben. Damit bleibt Lonheo operativ und finanziell stark.
Mit dieser strategischen Partnerschaft ist Lonheo in der Lage, unseren Kunden beim Erreichen ihrer Ziele zu helfen und ihnen einen größeren Mehrwert zu bieten.
Unser Unternehmen konzentriert sich auf Kabel & Draht-Versorgung und Abwasserbehandlung Chemikalien.
Unsere Eigenschaften Produkt:
===Stromkabel=== Ultra
Hochspannung, Stromkabel, Hochspannungs-Stromkabel, Mittelspannungs-Stromkabel, Niederspannungs-Stromkabel, LSZH (Low Smoke Zero Halogen) Kabel, XLPE Kabel, AAAC (Aluminiumlegierung Leiter) Stromkabel, gepanzertes Kabel, SWA (Stahldraht gepanzert) Kabel.
Stromkabel werden hauptsächlich für Stromübertragungs- und Verteilungssysteme in der Energiewirtschaft und allgemeinen Industrie verwendet.
===Drähte und Kabel für elektrische Geräte====
Gummi-isolierte Kabel, Bergbau-, Bohr- & Tunnelzug, Schiffskabel, Nylon ummantelte Drähte, Kunststoff-isolierte Steuerkabel.
Elektrische Betriebsmittelkabel werden hauptsächlich zur Versorgung und Verteilung von Elektrizität verwendet.
===Antennenkabel===
Antennenkabel, Kupferlitzen, ACSR-Drähte (ACSR), AAAC-Leiter (Aluminiumlegierung), AAC-Leiter (Aluminiumlitze).
Diese Kabel werden hauptsächlich als Freileitungen für die Stromübertragung und Energieverteilung verwendet.
===Spezielle Kabel und Drähte=== Feuerfestes
Kabel, Hochtemperaturbeständiges Kabel, Nagetier-/termitzicheres Kabel, Wasserdichtes Kabel, umweltfreundliches Gleichstromkabel, Mittelspannungsnetzkabel für U-Bahn und geringes Gewicht, Windenergie-Kabel, Atomkabel der Klasse 1E, energieeffizientes ACSR, UHV-tragende und expandierende Oberleitungen, Flexibles feuerfestes Kabel für 0,6/1KV.